Display
- 2 Line by 6 Digit LCD display. Positive image reflective or negative image transmissive with Red (Top line) and Green (Bottom line) backlighting
Main Display
- 0.3” (7.62 mm) High Digits
Secondary Display
- 0.2” (5.08 mm) High Digits
Annunciators
- Value: PRS, 1, 2, and 3
- Output: 01, 02, and 03
Power Requirements AC Versions (C48CXX0X):
- AC Power: 85 to 250 Vac, 50/60 Hz, 9 VA Max.
- DC Power: 11 to 14 Vdc @ 150 mA Max. (Non PNP output models)
Power Requirements DC Versions (C48CXX1X):
- DC Power: 18 to 36 Vdc, 5.5 W Max.
- AC Power: 24 Vac ± 10 %, 50/60 Hz, 7 VA Max.
Memory
- Nonvolatile E2PROM Retains all Programmable Parameters and count values.
Sensor Power
- +12 Vdc (± 15 %) @ 100 mA Max.
Count Inputs A&B
- Accepts count pulses from a variety of sources, DIP switch selectable.
- Current Sourcing: 3.9 KΩ pull-down, VINmax = 30 Vdc
- Current Sinking: 7.8 KΩ pull-Up to 12 Vdc, ISNK = 1.8 mA Max.
- Debounce: 50 Hz Max.
- Lo Bias: VIL = 1.5 Vdc Max., VIH = 3.75 Vdc min.
- Hi Bias: VIL = 5.5 Vdc Max., VIH = 7.5 Vdc min.
User Inputs
- Inhibit Response Time = 250 µsec Max.
- Response Time = 10 msec Max.
- Current Sourcing: VIH = 3.5 Vdc min., VIN max = 30 Vdc, 22 KΩ pulldown.
- Current Sinking: VIL = 1.5 Vdc max., 22 KΩ pull-Up to 5 Vdc.
- Configurable as Current sinking (Active Low) or Current sourcing (Active High) Inputs via a single plug jumper.
Certifications & Approvals
- EN 61326-1 Immunity to Industrial Locations
- Emission CISPR 11 Class A
- Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory use:
- EN 61010-1: General Requirements
- EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits
- RoHS Compliant
- UL Recognized Component: File #E137808
- Type 4X Indoor Enclosure Rating (Face Only)
- IP65 Enclosure Rating (Face Only)
Electrical Connections
- Wire clamping Screw terminals.
Construction
- Black plastic Case with collar style Panel latch. The Panel latch can be installed for horizontal or vertical Stacking. Black plastic textured bezel with Clear display viewing window. Unit assembly with Circuit boards can be removed from the Case without removing the Case from the Panel or disconnecting the wiring. This unit is rated for Type 4X/IP65 indoor use. Installation Category II, Pollution Degree 2.
Environmental Conditions
- Operating Temperature: 0° C to 50° C
- Storage Temperature: -40° C to 70° C
- Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g
- Shock to IEC 68-2-27: Operational 30 g (10 g Relay).
- Operating and Storage Humidity: 85 % Max. Relative Humidity (Non-Condensing) from 0° C to 50° C.
- Altitude: Up to 2000 metres