PD2-6001 Helios Feet & Inches Level Meter

Brand: Precision Digital Corporation

Go with the Helios PD2-6001 when you prefer to read level in feet and inches instead of the more common decimal format. 

This unique display will read up to 99 feet, 11 & 15/16s inches on the upper line. 

The lower line can display a tag or volume, even from non-linear tanks such as round horizontal ones. 

The PD2-6001 makes a great outdoor tank side indicator because its display is bright enough to read in direct sunlight and it will operate from -40° to 65° C (-40° to 150°F). 

The PD2-6001 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or controlling applications, including pump alternation control.
Features
  • Feet and Inches Display Ideal for Level Applications
  • Large 1.80ꞌꞌ Dual-Line 6-digit Display Readable from Up to 100' Away
  • Superluminous Sunlight Readable Display
  • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs
  • Universal 85 to 265 Vac, or 12 to 24 Vdc Input Power Models
  • Dual-scale for Some Level Applications - Single Input
  • Isolated 24 Vdc Transmitter Power Supply
  • Signal Input Conditioning for Round Horizontal Tanks
  • Programmable Display & Function Keys
  • 32-Point, Square Root, or Exponential Linearization
  • Multi-pump Alternation Control
  • Four - 4 Relays + Isolated 4-20 mA Output Option
  • Onboard USB & RS-485 Serial Communication Options
  • Modbus RTU Communication Protocol Standard
  • Program the Meter from a PC with Onboard USB and MeterView Pro

Specifications

Display

  • Two lines with 1.8” (46 mm) High Digits with feet & Inches Designations, Red LEDs, 6 Digits per line (-99999 to 999999), with Lead Zero Blanking

Feet & Inches Display Range

  • 0 to 99' 11-15/16”

Display Intensity

  • Eight intensity levels

Display Update Rate

  • 5/second (200 ms)

Overrange

  • Display flashes 999999

Underrange

  • Display flashes -99999

Display Assignment

  • The upper and Lower displays may be assigned to PV1, PV2, PCT (Percent), d r-u, d gross, d nt-g, max/min, alternate max. & min, Set Points, units (Lower display only), or Modbus Input.

Programming Methods

  • Four SafeTouch through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.

F4 Digital Input Contacts

  • 3.3 Vdc on Contact. Connect Normally Open Contacts across F4 to COM.

F4 Digital Input Logic Levels

  • Logic High: 3 to 5 Vdc, Logic Low: 0 to 1.25 Vdc

Noise Filter

  • Programmable from 2 to 199 (0 will disable filter)

Filter Bypass

  • Programmable from 0.1 to 99.9 % of Calibrated Span

Recalibration

  • Calibrated at the factory. Recalibration is recommended at Least every 12 months.

Maximum / Minimum Display

  • Maximum/minimum readings reached by the process are stored until reset by the user or until power to the meter is turned off.

Password

  • Three Programmable passwords restrict modification of programmed settings.

Non-Volatile Memory

  • All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.

Power Options

  • 5-265 Vac 50/60 Hz, 90-265 Vdc, 20 W max or 12-24 Vdc ± 10 %, 15 W Max. Powered over USB for configuration only.

Isolated Transmitter Power Supply

  • Terminals P+ & P-: 24 Vdc ± 10 %. 12-24 Vdc Powered models selectable for 24, 10, or 5 Vdc Supply (Internal P+/P- switch). 85-265 Vac models rated @ 200 mA max., 12-24 Vdc Powered models rated @ 100 mA max., @ 50 mA max. for 5 or 10 Vdc Supply.

Fuse

  • Required External Fuse: UL Recognized, 5 A max., Slow Blow, up to 6 metres may share one 5 A fuse.

Isolation

  • 4 kV Input/Output-to-Power Line, 500 V Input-to-Output or Output-to-P+ Supply

Overvoltage Category

  • Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.

Environmental

  • T6 Class Operating Temperature Range Ta = -40 to 60° C
  • T5 Class Operating Temperature Range Ta = -40 to 65° C
  • See LIM8 ProtEX-MAX instruction manual for additional details.

Maximum Power Dissipation

  • Maximum Power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.

Connections

  • Removable Screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external Relays, Digital I/O, and Serial communication Adapters.

Enclosure

  • UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic Case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, Black nylon threaded hole plugs with backing nuts.

Wall Mounting

  • Four (4) mounting holes provided for mounting meter to wall

Pipe Mounting

  • Optional Pipe Mounting Kit (PDA6260) Allows for Pipe Mounting. Sold Separately.

Dimensions

  • 10.63” x 12.59” x 4.77” (270 mm x 319.7 mm x 121.2 mm) (H x W x D)

Weight

  • 6.10 lbs (2.76 kg)

UL File Number

  • UL & C-UL Listed. E160849, 508 Industrial Control Equipment

Warranty

  • 3 Years Parts & Labor

USB Connection

  • Compatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle
  • Cable: USB A Male to Micro-B Cable Driver: Windows® 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows® 7 32/64-Bit, Windows® 10 32/64-Bit