PD6100 ProVu Strain Gauge, Load Cell & mV Digital Panel Meter

Brand: Precision Digital Corporation

The PD6100 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts strain gauge & load cell inputs and mV signals up to 300 mV: unipolar, and ± 250 mV: bipolar, for weight indication and force measurement applications. 

The PD6100's dual-line display and powerful dual-scale capability allows the measurement to be displayed in two different units of measure; gallons: volume, could be displayed on the upper line while pounds: weight, is displayed on the lower line, for example.

Another use for the PD6100's dual-line display is to simply show the units of measure on the bottom line.

The PD6100 stain gauge meter includes a 5 or 10 VDC power supply to drive the sensors and can be equipped with up to four internal relays and one 4-20 mA output.
Features
  • 15, 30, 150, 300 mV Unipolar Input Ranges
  • ±15, ±25, ±150, ±250 mV Bipolar Input Ranges
  • Selectable 5 or 10 Vdc Sensor Excitation
  • Capture or Programmable Tare Feature
  • Auto-Zero Feature Eliminates Zero Drift
  • Ratiometric Operation
  • Max/Min or Peak/Valley Hold Feature
  • Large Dual-Line 6-Digit Display, 0.60" & 0.46"
  • Dual-Scale Feature - Single Input
  • Rounding Function 1, 2, 5, 10, 20, 50 or 100
  • Programmable Display & Function Keys
  • 32-Point Linearization
  • NEMA 4X, IP65 Front
  • Universal 85-265 Vac, or 12/24 Vdc Input Power Models
  • 2 or 4 Relays + Isolated 4-20 mA Output Options
  • External 4-Relay & Digital I/O Expansion Modules
  • USB, RS-232 & RS-485 Serial Communication Options
  • Modbus RTU Communication Protocol Standard
  • Configure, Monitor, and Data Log from a PC with Free MeterView Pro Software

Specifications

Approvals & Certifications

  • UL

Communication

  • RS-232
  • RS-485
  • USB

Deadband

  • 0 to 100 % of Span

Enclosure, Body Material

  • High Impact Plastic

Environmental Protection

  • IP65
  • IP66
  • NEMA 4X

Humidity

  • 0 to 90 % Non-Condensing

Isolation

  • 4 kV Input/Output-to-Power-Line
  • 500 V Input to Output or Output to P+ Supply

Mounting

  • 1/8” DIN

Operating Temperature

  • -40° to 65° C (-40° to 150° F)

Output

  • 4-20 mA

Relay Output

  • 2 or 4 SPDT
  • 4 SPST

Supply Voltage

  • 90-265 Vdc

Torque

  • 5 In/Lbs
show more