Model PAX - 1/8 DIN Digital Input Panel Meters
Brand: Red Lion ControlsThe PAX Digital Input Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications.
Available in three different models, PAXC Counter/Dual Counter, PAXR Rate Meter and the PAXI which offers both counting and rate in the same package. Refer to pages 4 - 5 for the details on the specific models.
The PAXC and PAXR offer only the Setpoint Option, while the PAXI is the fully featured version offering all the capabilities as outlined in this bulletin as well as a slave display feature.
The option cards allow the opportunity to configure the meter for present applications, while providing easy upgrades for future needs.
The meters employ a bright 0.56" LED display. The meters are available with a red sunlight readable or standard green LED display. The intensity of the display can be adjusted from dark room applications up to sunlight readable, making it ideal for viewing in bright light applications.
The meters accept digital inputs from a variety of sources including switch contacts, outputs from CMOS or TTL circuits, magnetic pickups and all standard RLC sensors. The meter can accept directional, uni-directional or Quadrature signals simultaneously.
The maximum input signal varies up to 34 KHz depending on the count mode and function configurations programmed. Each input signal can be independently scaled to various process values.
The Rate Meters provide a MAX and MIN reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events.
Optional digital output cards provide the meter with up to four setpoint outputs. The cards are available as dual relay, quad relay, quad sinking transistor, quad sourcing transistor/SSR drive, or dual triac/dual SSR drive outputs.
The setpoint alarms can be configured to suit a variety of control and alarm requirements.
Communication and Bus Capabilities are also available as option cards for the PAXI only. These include RS232, RS485, Modbus, DeviceNet, and Profibus-DP. Readout values and setpoint alarm values can be controlled through the bus.
Additionally, the meters have a feature that allows a remote computer to directly control the outputs of the meter. With an RS232 or RS485 card installed, it is possible to configure the meter using Red Lion’s Crimson software. The configuration data can be saved to a file for later recall.
A linear DC output signal is available as an option card for the PAXI only. The card provides either 20 mA or 10 V signals. The output can be scaled independent of the input range and can track any of the counter or rate displays.
Once the meters have been initially configured, the parameter list may be locked out from further modification in its entirety or only the setpoint values can be made accessible.
The meters have been specifically designed for harsh industrial environments. With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE requirements, the meter provides a tough yet reliable application solution.
Features- 1/8 DIN (50 mm x 97 mm)
- 6 Digit, 0.56" (14.2 mm) LED Display
- User Selectable Input Modes
- Rate Indication
- Up to 3 Count Displays or a Serial Slave
- Four Setpoint Alarm Outputs
- Communications and Bus Capabilities
- Analog Output Signal
- PC Software Available for Meter Configuration
- NEMA 4X/IP65
Specifications
Brand
Display
- 6 Digit, 0.56” (14.2 mm) Red sunlight Readable or Standard Green LED
Power AC
- AC Power: 85 to 250 Vac, 50/60 Hz, 18 VA Isolation: 2300 Vrms for 1 min. to all Inputs and outputs. (300 V working)
Power DC
- DC Power: 11 to 36 Vdc, 14 W (Derate Operating Temperature to 40° C if Operating < 15 Vdc and three option Cards are installed) AC Power: 24 Vac, ± 10 %, 50/60 Hz, 15 VA Isolation: 500 Vrms for 1 min. to all Inputs and outputs (50 V working)
Sensor Power
- 12 Vdc, ± 10 %, 100 mA Max. Short Circuit Protected
Keypad
- 3 Programmable function keys, 5 keys total
User Inputs
- Logic State: Jumper selectable for sink/source logic
- Isolation to Sensor Input Commons: Not isolated
- Maximum Continuous Input: 30 Vdc
Output
- Timed Output Accuracy: Counter = ± 0.01 % + 10 msec. Rate = ± 0.01 % + 20 msec
- Response Time: 25 µsec., add 6 msec (Typical) if a Relay Card is installed
Memory
- Nonvolatile memory Retains all Programmable Parameters and display values when Power is removed.
Certifications & Approvals
- IP20 Enclosure Rating (Rear of unit)
- IP65 Enclosure Rating (Face Only)
- Type 4X Indoor/Outdoor Enclosure Rating (Face Only)
- UL Listed: File #E137808
- UL Recognized Component: File #E179259
- EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits
- EN 61010-1: General Requirements
- Emission CISPR 11 Class A
- EN 61326-1 Immunity to Industrial Locations
- RoHS Compliant
Environmental Conditions
- Altitude: Up to 2000 metres
- Shock to IEC 68-2-27: Operational 25 g (10 g Relay)
- Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g
- Operating and Storage Humidity: 0 to 85 % Max. Relative Humidity (Non-Condensing)
- Storage Temperature Range: -40 to 60° C
- Operating Temperature Range: 0 to 50° C (0 to 45° C with all three Cards installed)
Connections
- Torque: 4.5 inch-lbs (0.51 N-m) max
- Wire Gage: 30-14 AWG Copper wire
- Wire Strip Length: 0.3” (7.5 mm)
- High Compression Cage-Clamp Terminal Block
Construction
- This unit is rated for Type 4X/IP65 use. IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece bezel/case. Flame resistant. Synthetic Rubber keypad. Panel gasket and Mounting clip included.
Weight
- 10.1 oz. (286 g)