Display
- Dual-line LCD with backlight
- Both lines 14-segment alphanumeric
- Top: 0.7" / 17.8 mm
- Bottom: 0.4" / 10.2 mm
- Display may be programmed to turn red and flash a user-defined message on alarm condition
- PD6603 & PD6607 only: Top line: 7-segment numeric, FT-IN
- Bottom line: 14-segment alphanumeric
Operating Temperature Range
- -40° to 75° C for Safe Area Products
- -40° to 70° C for Hazardous Area Products
Storage Temperature Range
Relative Humidity
- 0 to 90 % Non-condensing
- Printed circuit boards are conformally coated
Connections
- Removable screw terminals accept 12 to 22 AWG wire
Overall Dimensions
- 4.68"x 2.45"x 3.79"
- 119 mm x 62 mm x 96 mm
- W x H x D
Weight
- 8.7 oz. / 247 g with option board
Hazardous Area Approvals
- ATEX: II 1G, Ex ia IIC T4 Ga, Ta = -40° to +70° C Certificate Number: CML 17ATEX2015X
- IECEx: Ex ia IIC T4 Ga, Tamb = -40° to +70° C Certificate Number: IECEx CML 17.0008X
- UL & cUL Listed as Intrinsically Safe and Nonincendive: Class I, Div. 1, Groups A, B, C and D T4, Class I, Div. 2, Groups A, B, C and D T4 Ex ia IIC T4 (Canada), Class I Zone 0, Zone 1 AEx ia IIC T4 (U.S.) Class I Zone 2, Group IIC T4 (U.S.) PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS
- UL & cUL 61010 Listed for Electrical Safety and Type 4X Environmental: Standards for Safety: IEC 61010-1:2010 (3rd Edition), UL 61010-1, 3rd Edition, CAN/CSA C22.2 No. 61010-1-12, 3rd Edition, Additional Standards: UL 50E